Item In Stock
A screw-in, cartridge-style, fi xed orifice, pressure-compensated, hydraulic flow regulating valve (restrictive type).
The FR16-20F maintains a constant flow rate out of β regardless of load pressure changes in the circuit downstream of βThe fi xed control orifice is factory preset to customer flow specifi cation. The valve
begins to respond to load changes when the flow through the valve creates a
pressure differential across the control orifice greater than 5.5 bar (80 psid), with
accurate flow maintenance from 7.6 to 240 bar (300 to 3500 psid). Reverse flow
(β to β) returns through the control orifice and is non-compensated.
• Hardened parts for long life.
• Quiet, modulated response.
• Cost-effective cavity.
Operating Pressure: 240 bar (3500 psi)
Flow Settings: 4 lpm (1 gpm) min; 113 lpm (30 gpm) max.
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC16-2; See page 9.116.1
Cavity Tool: CT16-2XX; See page 8.600.1
Seal Kit: SK16-2X; See page 8.650.1