PS08-35 Sequence, External Pilot, Internal Drain

PS08-35   Sequence, External Pilot, Internal Drain

PS08-35 Sequence, External Pilot, Internal Drain (PS08-35)

Item In Stock

Product Description

A screw-in, cartridge-style, direct-acting, spool-type, hydraulic sequence valve with external pilot and internal spring chamber drain.

Product Operation

In its steady state, the PS08-35 allows flow from ➁ to ➂On attainment of a pre-determined pressure at ➀, the cartridge shifts to close ➁ to ➂Since the spring chamber is vented at ➂, back pressure at ➂ will directly (1:1) affect the valve’s setting.

Product Features

Adjustments cannot be backed out of the valve.
Adjustments prohibit springs from going solid.
Optional spring ranges to 165.5 bar (2400 psi).
Hardened spool and cage for long life.
Compact size.

Product Ratings

Operating Pressure: 240 bar (3500 psi)
Flow: See Performance Chart
Internal Leakage: 82 cc/minute (5 cu. in./minute) max. at full close
Standard Spring Ranges: 3.4 to 20.7 bar (50 to 300 psi); 6.9 to 41.4 bar (100 to 600 psi); 10.3 to 89.7 bar (150 to 1300 psi); 20.7 to 165.5 bar (300 to 2400 psi)
Temperature: -40 to 120°C with standard Buna seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC08-3; See page 9.108.1
Cavity Tool: CT08-3XX; See page 8.600.1
Seal Kit: SK08-3X-BM; See page 8.650.1