4-20 mA Input

4-20 mA Input

4-20 mA Input (4)

Item In Stock

Product Description

A DIN rail-mount style control amplifier for HydraForce proportional valves. Remote mounting in a protected enclosure is required. This model is designed for circuits with long wire runs or where electrical interference is a problem.

Product Operation

This control module uses closed-loop current control with superimposed dither to supply a proportional valve solenoid with a proportional control signal. The input
signal to this controller can be from a 4–20 mA source.

Product Features

Adjustments and connections clearly labeled.• LED indication of output power level, input level and power on/off.
One unit covers supply voltages from 9 to 32 VDC.
No internal fuses; circuit limits current electronically.
Short circuit proof and reverse polarity protected.
Can be disconnected from coil when powered.
Maximum current adjustment does not affect minimum current setting.• Current sensing circuit maintains output current regardless of changes in input voltage or coil resistance.• Filter eliminates electrical noise;
Independent ramp adjustments.
Dither frequency and amplitude are adjustable for maximum valve performance.

Product Ratings

Supply Voltage: 9–32 VDC Coil rating must be matched with supply voltage: RCOIL ≤ (VSUPPLY – 1.5 V) / I-Max.
Control Input Signal: 4–20 mA current signal (see connection diagram)
Input Resistance: 50 Ohms
Output Current: up to 2000 mA (see ordering info.)
Minimum Current Range: 0–500 mA (adjustable)
Maximum Current Range: 600–2000 mA (adjustable)
Ramp Up and/or Down: 0.01–5.0 seconds (independently adjustable)
Dither Frequency: 70–350 Hz (±10%)
Dither Amplitude: 0–10% of maximum current (adjustable)
Operating Conditions: –20° to 85°C; 0 to 85% relative humidity
3.436.1
Proportional Valve Controller—DIN Rail Mount—
SCHEMATICSTEP-DOWNCONVERTERVPS TO 5.5 VSTEP-UPDC/DCCONVERTERINPUT, OUTPUTANDPOWER SUPPLYINDICATORSSOLENOIDOUTPUTDITHERAMPLITUDEACTIVEREVERSE POLARITYPROTECTIONDITHERGENERATORCURRENT SENSING AND SHORT CIRCUITPROTECTIONVPS POWERGNDCURRENT LOOP TRANSMITTER+–S2S1RMI-MAX.RAMP UPRAMP DOWNRMAX.ERRORAMPLIFIERLOWPASSFILTER+–RDARMIN.I-MIN.+5 VRDDITHER FREQUENCYRDITHERINDEPENDENTRAMP CONTROLFUNCTIONVOLTAGETO HIGH FREQUENCYPWMCONVERTERANALOG GNDCURRENT IN(4-20 mA)NOT USEDENABLENOT USED+12 V–12 V+5 V(9-32 VDC)CF
GENERAL SPECIFICATIONS
Weight: 25 g (0.88 oz.)
Connections: Screw terminals for 16–30 AWG wire
CSA Listing:CSA C22.2 No. 14-M91