SVCV08-20 Poppet, 2-Way, Normally Closed . . .

SVCV08-20   Poppet, 2-Way, Normally Closed . . .

SVCV08-20 Poppet, 2-Way, Normally Closed . . . (SVCV08-20)

Item In Stock

Product Description

A solenoid-operated, two-way, pilot-operated, poppet-type, normally closed, screw-in hydraulic cartridge valve with outlet flow check, designed for low leakage in load holding applications.

Product Operation

When de-energized, the SVCV08-20 blocks flow from ➁ to ➀ and from ➀ to ➁When energized, the cartridge’s poppet lifts to open the ➁ to ➀ flow path, while continuing to block flow from ➀ to ➁The SVCV08-20 is designed to fi t into the VC08-3 cavity with the normal inlet at cav-
ity port 3 (valve port ➁), the outlet at cavity port ➀ (valve port ➀), and cavity port ➁ blocked. The pressure drop will be substantially higher if cavity port ➁ is selected as an alternate outlet port.
Operation of Manual Override Option: To override, push button in, twist counter-
clockwise 180°, and release. In this position, the valve will remain open.
To return to normal operation, push button in, twist clockwise 180°, and release.
Override will be detented in this position.

Product Features

Continuous-duty rated coil.
Hardened seat for long life and low leakage.
Optional coil voltages and terminations.
Manual override option.
Cartridges are voltage interchangeable.
Optional waterproof E-Coils rated up to IP69K.
Industry common cavity.
Compact size.

Product Ratings

Operating Pressure: 207 bar (3000 psi)
Rated Flow: 22.7 lpm (6 gpm)
Reverse Flow Check Valve Spring: 0.69 bar (10 psi)
Maximum Internal Leakage: ➁ to ➀: 5 drops/minute at 207 bar (3000 psi); ➀ to ➁: 10 drops/minute at 207 bar (3000 psi)
Temperature: -40 to 120°C with standard Buna seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Response Time: First indication of change of state with 100% voltage supplied at 80% of nominal flow rating:Energized: 40 msec.; De-energized: 46 msec.
Initial Coil Current Draw at 20°C: Standard Coil: 1.2 amps at 12 VDC; 0.13 amps at 115 VAC (full wave rectifi ed); E-Coil: 1.4 amps at 12 VDC; 0.7 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC08-3; See page 9.108.1
Cavity Tool: CT08-3XX; See page 8.600.1
Seal Kit: SK08-3X-M; See page 8.650.1
Coil Nut: Part No. 7004400