SV10-28

SV10-28

SV10-28 (SV10-28)

Item In Stock

Product Description

A solenoid-operated, 2-way, normally closed, internally piloted, poppet-type, bi-directional blocking, screw-in hydraulic cartridge valve, designed for low leakage in load-holding applications.

Product Operation

When de-energized, the SV10-28 blocks flow in both directions. When energized, the
valve’s poppet opens on its seat, allowing flow from ➁ to ➀ or ➀ to ➁

Product Features

Continuous-duty rated coil.
Optional coil voltages and terminations.
Cartridges are voltage interchangeable.
Optional waterproof E-Coils rated up to IP69K.
Hardened seat for long life and low leakage.
Manual override option.
Industry common cavity.

Product Ratings

Operating Pressure: 240 bar (3500 psi)
Flow: 75.7 lpm (20 gpm)
Internal Leakage: 0.25 cc/minute (5 drops/minute) max. at 240 bar (3500 psi)
Temperature: -40 to 120°C with standard Buna seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Response Time: First indication of change of state with 100% voltage supplied at 80% of nominal flow rating: Energized: 40 msec.; De-energized: 32 msec.
Initial Coil Current Draw at 20°C: Standard Coil: 1.67 amps at 12 VDC; 0.18 amps at 115 VAC (full wave rectifi ed). E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 240 bar (3500 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-2; See page 9.110.1
Cavity Tool: CT10-2XX; See page 8.600.1
Seal Kit: SK10-2X-M; See page 8.650.1
Coil Nut: Part No. 7004400; For E-coils manufactured prior to 1-1-04, see page 3.400.1 for coil nut info.