PCV10 Check, Pilot-to-Open

PCV10   Check, Pilot-to-Open

PCV10 Check, Pilot-to-Open (PCV10)

Item In Stock

Product Description

An in-line-housed, pilot-operated, hydraulic check valve for use in blocking or load-holding circuits.

Product Operation

The PCV10 allows flow from B to A, while normally blocking flow from A to B.
Flow will be allowed from A to B when pressure is applied at X.
The check valve has a 4:1 pilot ratio, meaning that at least one-fourth of the load
pressure held at A is required at X to open the valve.
The check is spring-biased at 2 bar (30 psi) to assure holding in static or no-load
conditions. A sealed pilot piston option with check spring bias of 6.9 bar (100 psi)
is available.

Product Features

Hardened seat for long life and low leakage.
Optional sealed pilot piston.• Optional spring ranges.
Check section is serviceable as a cartridge.

Product Ratings

Operating Pressure: 240 bar (3500 psi)
Flow: See Performance Chart
Internal Leakage: A to B: 0.25 cc/minute (5 drops/minute) max. at 240 bar (3500 psi); B to X (without sealed piston): 245 cc/minute (15 cu. in./minute) max. at 240 bar (3500 psi)
Pilot Ratio: 4:1
Temperature: -40 to 120°C with standard Buna seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Check Spring Bias: 2 bar (30 psi); with sealed piston option, 6.9 bar (100 psi)
Seal Kit (for CV10-20):
SK10-2X-T; See page 8.650.1; Piston Seal: See Dimension Drawing
Pilot Piston Service Part Numbers: O-Ring (1): Buna 6001014; Fluorocarbon 6003014 Back-ups (2): Buna 6011014; Fluorocarbon 6011014