HPV12-30 HyPerformance™ Proportional Flow,

HPV12-30   HyPerformance™ Proportional Flow,

HPV12-30 HyPerformance™ Proportional Flow, (HPV12-30)

Item In Stock

Product Description

A high pressure, solenoid-operated, electrically-variable, three-port, pressure-compensated, spool-type, normally closed when de-energized, proportional flow control valve. It can be used as a priority-type flow regulator with pressure-compen-sated, regulated and bypass flow. It can also be used as a restrictive-type 2-way, pressure-compensated flow regulator when the bypass line (port 2) is blocked.

Product Operation

The HPV12-30 will regulate flow out of port 3 regardless of system working pressure. With an increasing current applied to the solenoid, the HPV12-30 will increase output flow.
Note: When used as a bypass flow control in applications where the priority flow port will be blocked by external valving, bypass pressure drop will increase unless a small amount of leakage is provided for the priority port. Consult factory.

Product Features

Excellent linearity and hysteresis.
Hardened spool and cage for long life.
Optional coil voltages and terminations.
Efficient wet armature construction.
Cartridges voltage-interchangeable.
Unitized, molded coil design.
Coil waterproofing standard.• All HyPerformance™ products are tested to the rigorous standards of the NFPA specification T2.6.1.• All HyPerformance™ valves are tested at a verification level of 90% and an assurance of 99%.

Product Ratings

Operating Pressure: 350 bar (5075 psi); 10% life cycle 420 bar (6090 psi) Note: All HyPerformance™ products are tested for 900K cycles at 350 bar and 100K cycles at 420 bar.
Proof Pressure: 690 bar (10,000 psi)
Burst Pressure: 1380 bar (20,000 psi)
Regulated Flow Rate: 76 lpm (20 gpm) nominal input; 114 lpm (30 gpm) maximum input; priority type 66 lpm (17.5 gpm) maximum; restrictive type 60 lpm (16 gpm) maximum.
Max. Internal Leakage: 380 ml/min. (0.10 gpm) at port 3 at 0 current with 350 bar(5075 psi) at port 1 (port 2 blocked)
Temperature: -54°C - 107°C (-65°F - 225°F) with PPDI Urethane seals
Hysteresis: ±1.9 lpm (0.50 gpm) maximum
Dither/PWM Frequency Range: 100 to 250 Hz
Electrical Parameters (with size 10 E-series coil):
Coil
Voltage12 VDC24 VDC
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1.
Cavity: HVC12-3; See page 9.112.1
Cavity Tool: HCT10-3X-XX; See page 8.600.1
Seal Kit: HSK12-3X-0; See page 8.650.1 for seal kit options and appropriate seals based on application temperature range.
Coil Nut: Part No. 7004420213
ISO SYMBOL
2.371.1