PV76-30A Proportional Flow Control Cartridge,

PV76-30A   Proportional Flow Control Cartridge,

PV76-30A Proportional Flow Control Cartridge, (PV76-30A)

Item In Stock

Product Description

A solenoid-operated, electrically-variable, three-port, pressure-compensated, spool-type, normally closed when de-energized, proportional flow control valve. It can be used as a priority-type flow regulator with pressure-compensated, regulated and bypass flow. It can also be used as a restrictive-type 2-way, pressure-compensated flow regulator when the bypass line (port ➁) is blocked.

Product Operation

The PV76-30A will regulate flow out of port ➂ regardless of system working pressure. With increasing current applied to the solenoid, output flow will increase.
Note: When used as a bypass flow control in applications where the priority flow port
will be blocked by external valving, bypass pressure drop will increase unless a small
amount of leakage is provided for the priority port. Consult factory.
Operation of Manual Override: To Engage: Turn clockwise approximately 1 turn to
reach start point. Continue another approximately 5 turns to full shift. To Disengage:
Turn counterclockwise approximately 6 turns to positive stop.

Product Features

Excellent linearity and hysteresis characteristics.
Hardened spool and cage for long life.
Optional coil voltages and terminations.
Effi cient wet armature construction.

Product Ratings

Operating Pressure: Inlet: 240 bar (3500 psi); Ports ➁ and ➂: 207 bar (3000 psi)
Regulated Flow Rate: Range A: 3-Ported: 94.6 lpm (25.0 gpm)
Range A: 2-Ported: 85.2 lpm (22.5 gpm)
Nominal Input Flow: Bypass Open, 3-Ported: 121 lpm (32.0 gpm)
Maximum Input Flow: Bypass Open, 3-Ported: 151.4 lpm (40.0 gpm)
Internal Leakage: 0.38 lpm (0.10 gpm) at zero current
Electrical: 2 standard voltage ratings
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1.
Cavity: VC16-3; See page 9.116.1;
Cavity Tool: CT16-3X-XX; See page 8.600.1
Seal Kit: SK16-3X-MM; See page 8.650.1 for seal kit options and appropriate seals based on application temperature range.