NV08-21 Needle Valve with Positive Shut-Off

NV08-21   Needle Valve with Positive Shut-Off

NV08-21 Needle Valve with Positive Shut-Off (NV08-21)

Item In Stock

Product Description

A screw-in, cartridge-style, variable orifice, hydraulic flow restrictor valve. It is intended for applications requiring fi ne adjustment over multiple turns.

Product Operation

The NV08-21 increases its orifice value from fully closed to fully open with adjustment
rotation in the counterclockwise direction. Effective adjustment is linear to eight turns.
Note: This is intended as a low-effort adjustment suitable for operation through
linkage. It may be unsuitable in environments where vibration is present.

Product Features

Adjustment cannot be backed out of the valve.
Hardened parts for long life.
Industry common cavity.
Fine/low effort adjustment.
Positive shut-off.
Linear adjustment.

Product Ratings

Operating Pressure: 240 bar (3500 psi)
Flow: See Performance Chart
Internal Leakage: 0.25 cc/minute (5 drops/minute) max. at shut-off
Adjustment Torque Required: 0.34 Nm (3 inch-pounds) at 7 bar (100 psi); 0.68 Nm (6 inch-pounds) at 207 bar (3000 psi)
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC08-2; See page 9.108.1
Cavity Tool: CT08-2XX; See page 8.600.1
Seal Kit: SK08-2X-M; See page 8.650.1
PERFORMANCE (Cartridge Only)