EC42-M42 Pressure Compensator

EC42-M42   Pressure Compensator

EC42-M42 Pressure Compensator (EC42-M42)

Item In Stock

Product Description

A screw-in, cartridge-style priority-on-demand pressure-compensator with static load sense.

Product Operation

The EC42-M42 provides priority flow in the required amount, while allowing excess
flow to be used for auxiliary functions. With port ➂ providing inlet flow, port ➃ will deliver the required priority flow regardless of load pressure. Excess flow exits at ➁. Port ➀ is the load sense port. All ports may be fully pressurized.NOTE: 0.031 in. (0.79 mm) orifice is recommended to be installed in the load sense
line at port ➀ for better stability.

Product Features

Hardened parts for long life.
Quiet, modulated response.
Industry common cavity.

Product Ratings

Operating Pressure: 241 bar (3500 psi)
Maximum Input Flow: 303 lpm (80.0 gpm)
Maximum Priority Flow: 208 lpm (55.0 gpm) with 10.3 bar (150 psi) spring; 151 lpm (40.0 gpm) with 5.5 bar (80 psi) spring
Maximum Bypass Flow: 208 lpm (55.0 gpm) with 10.3 bar (150 psi) spring; 151 lpm (40.0 gpm) with 5.5 bar (80 psi) spring
Flow Maintenance: see performance chart
Temperature: -40 to 120°C with Buna N seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC42-M4; See page 9.142.1
Cavity Tool: CT42-M4XX; See page 8.600.1
Seal Kit: SK42-4X-MMM; See page 8.650.1