Item In Stock
A screw-in, cartridge-style, priority-on-demand, pressure compensator with static load sense intended to provide priority flow in the required amount, while allowing excess flow to be used for auxiliary functions.
With inlet flow at port ➂, the EC12-42 will deliver required priority flow at port ➃, based on the size of the external orifice, regardless of load pressure. Excess flow
exits, or is bypassed, at port ➁. Port ➀ is the load sense port. All ports may be fully pressurized.
• Hardened parts for long life.
• Quiet, modulated response.
• Industry common cavity.
Operating Pressure: Inlet: 345 bar (5000 psi); Note: Steel body required when used at or near 5000 psi.
Maximum Regulated Flow: 76 lpm (20 gpm) with 160 psi compensating spring; 54.5 lpm (14.4 gpm) with 80 psi compensating spring
Flow Maintenance: See performance chart
Temperature: -40 to 120°C with Buna N seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC12-4; See page 9.112.1
Cavity Tool: CT12-4-XXX; See page 8.600.1
Seal Kit: SK12-4X-MMM; See page 8.650.1